Information Name: | Magnetic detectors - Surface Flaw |
Published: | 2014-12-26 |
Validity: | 30 |
Specifications: | 340mmX300mmX250mm |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Product Overview CDX-III magnetic detectors is the company absorbed the advantages of similar products at home and abroad to design and production of new magnetic detection equipment. Using external magnetic field magnetization method, the instrument has a small size, light weight advantages. Highly integrated circuit enables a single device combines all the features of the original in several devices. ◆ mainly for functional use of ferromagnetic material surface and near surface inspection, exchange of electromagnetic method can detect injury is less than 2mm. ◆ a device compatible with A, D, E, O four kinds of probes, a plurality of types of the workpiece to meet customer demand. ◆ magnetization using a variety of methods, non-contact switch, low noise, long life, applicability, stable. ◆ use of isolation transformers to probe provides 36V power supply, low voltage output, safe and reliable, long working life. ◆ equipment is small, light weight, lifting force, each probe live joint adjustable. ◆ handheld operation, simple and quick. Can be carried to the workshop, laboratory and field testing workplace. ◆ widely used in aerospace, aviation, railway, automobile, shipbuilding, pressure vessels, machinery, buildings, bridges and other industries. Works utilizing magnetic particle inspection and magnetic particle interaction artifacts leakage field defects, and it takes advantage of the steel product surface and near-surface defects (such as cracks, slag, hairline, etc.) differences in permeability and permeability of the steel, the magnetization These materials are not magnetic discontinuities of distortion will occur, leakage flux at the surface portion is formed to produce a leakage field, thereby attracting magnetic particles to form magnetic particle accumulation of defects - magnetic marks, showing ferromagnetic materials by means of magnetic particle leakage field The distribution, which found that the material surface or near-surface defects location and shape, to observe and interpret these magnetic powder to accumulate, to achieve a magnetic particle inspection. Working conditions Temperature: -10 ℃ ~ + 40 ℃; Humidity: relative humidity less than 85 technical parameters 1, Power: AC 220V ± 10% 50HZ 5A 2, Output: AC 36V 10A optional ADEO four kinds of probe 3, testing speed : ≥6 m / min 4, the probe temperature: ≤60 ℃ 5, the work of Beat: Working long hours is recommended when: magnetizing time ≤3 seconds, 6 seconds gap time ≥5, Instrument Weight: about 6.6Kg Instrument features non-destructive, simple operation, low detection cost, intuitive display. A probe: also known as Horseshoe yoke probe or fillet weld probe head bevel joint activities with work lights; on the contoured surface, especially for complex shape of the workpiece inspection. Polar distance: 20-160mm; lifting force: AC≥5Kg DC≥18Kg; Weight: 1Kg. Using this probe can be made independent of a horseshoe magnetic detectors or magnetic detectors fillet. D-type probe: also known as electromagnetic yoke probe, high permeability greater joint activities multipolar magnetization. Polar distance: 60-220mm; lifting force: AC≥6Kg DC≥18Kg; Weight: 1.6 Kg. Using this probe can be made independent of a magnetic yoke magnetic detectors. O-type probe: also known as ring probe generates a magnetic field when the coil is energized by inductively magnetized piece; a variety of small parts may mandrel type, bolts and other testing or demagnetization away from law-through. Inner diameter: 150mm center field ≥ 180oe Weight: 3Kg. Operating methods and precautions Notes (1) The instrument Beat: Working long hours is recommended when: magnetizing time ≤3 seconds, the time between the interest ≥5 seconds. (2) should be checked before using the instrument meets the requirements of the supply voltage, such as too high or too low may damage the instrument or affect testing results. (3) When using the probe end should be kept in good contact with the piece to be checked, then press the magnetizing switch, then magnetization best results. (4) Notwithstanding the good of the instrument load current protection circuit, but when used, should try to avoid work load in order to reduce unnecessary temperature rise. (5) The instrument can work continuously, as found in some serious heat stop using reason to be identified before use. (6) instruments and accessories should be clean, dry, non-corrosive environments or storage. (7) at the time of self-repair, please note that the machine high risk. (8) Press the switch magnetization work, not switching power supply. (9) The instrument housing must be grounded. (10) If you can not repair electrical fault, please send the instrument back to our service center. Instrument Care and Maintenance Troubleshooting (1) power on no instructions, no work, fuse, causing a short circuit or overload. (2) the switch is pressed, the probe work, no work instructions, damage caused due to work lights. (3) work lights, the probe is not magnetized, the main circuit or control circuit failure. (4) power, not by magnetizing switch that magnetization, triac control circuit or bad. Copyright 2012 -? 2014 Xing Billiton Songyuan Copyright Beijing ICP 14009359 No. |
Admin>>>
You are the 4307 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Xing Extension Source Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 4307 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Xing Extension Source Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility